ROTO-BIN-DICATOR®

Point Level Measurement

The Roto-Bin-Dicator is the most universal of all level sensing technologies and is the most popular level switch used in dry bulk materials. The Roto-Bin-Dicator is a rotating paddle type, bulk material level sensor offered with a wide variety of paddle options for unequaled application versatility. It is easy to install and requires no special tools or calibrations.

Specification Sheets:
Manual:

Technical Specification

Operating Power24/120/240 VAC; 50/60 Hz, 24 VDC
Power Consumption5 watts
Switch or Relay OutputSPDT 20A @ 125/250/480 VAC
Process Temperature-20º F to 302º F (-29º C to 150º C) Standard; Up to 500º F (260º C) with Extension 3 and Lag
Conduit Entry3/4” NPT or M20 x 1.5

Product Details

THE ORIGINAL

Introduced to the dry bulk industry in 1954, Roto-Bin-Dicator is the original rotating paddlewheel type dry bulk level indicator. This well-proven, easy to use, simple to install product remains the leader in dry bulk level indication in tanks and silos around the world.

UNMATCHED FLEXIBILITY

With an extensive choice of paddle options, the Roto can adapt to a variety of applications and materials. These paddlewheel switches can be mounted vertically or horizontally in a tank with extended shafts if required.

Technology:Paddlewheel
Applications:Universal, dry bulk point level detection

PADDLE OPTIONS

An extensive list of paddle and extension options, the Roto can adapt to a variety of applications and materials; paddles range from a 4-vane to curved to 90 degree and all extensions can be customized to fit the tank or vessel.

VERSATILE MOUNTING OPTIONS

The Roto-Bin-Dicator is designed to fit into almost any environment. The housing can have either imperial or metric conduit entries, and the process fitting can be made to fit essentially any connection type or thread.

GLOBAL APPROVALS

Roto-Bin-Dicator is available with UL approval (for both the US and Canada) and CE marking (electromagnetic compatibility and low voltage directives) for ordinary locations or explosion proof and dust ignition proof hazardous area ratings.

Download

Specification Sheets:
Manual:
Drawing: